Whirlpool Duet Diagnostic Test Mode
NOTE: The control must be in the OFF state before pressing the touch-pad sequence to start the test.
1. Close the door.
2. Press the Control On button.
3. Select the DRAIN/SPIN cycle.
4. Select NO SPIN by pressing the SPIN SELECT button, as needed.
5. Push Prewash Option button four times within five seconds. C:00 will show in the display.
NOTE: If Model does not have PREWASH Mode as an option, press RINSE/HOLD.
If the Starting procedure fails, push PAUSE/CANCEL button. Then repeat the starting sequence again.
To advance to the next step of the test procedure, push Prewash Option button two times.
Whirlpool Duet Test Overview
Indication |
Control Action |
Actuators to be Checked |
C:00 |
Door is Locked |
Door Lock System |
C:01 |
Filling by cold water inlet valve |
Flowmeter, Cold water inlet valve |
C:02 |
Distribution system is set to Prewash position |
Dispenser motor, |
C:03 |
Fill by hot water inlet valve |
Hot water inlet valve |
C:04 |
Basket rotates clockwise at wash speed |
Motor, MCU control |
C:05 |
Heater is switched ON. |
Heater, Temperature Sensor |
C:06 |
Drain Pump is ON |
|
C:07 |
Basket rotates counterclockwise |
Motor, MCU control |
C:08 |
Basket rotates counterclockwise |
Motor, MCU control |
Whirlpool Duet Component Testing
CENTRAL CONTROL UNIT (CCU)
NOTE: Connector Test Points Are Numbered 1234567 From Right To Left When The Connector Is Plugged In Looking From Behind
Whirlpool Duet Dispenser Switch and Motor
Switch Test Points 6 & 5 = 0 ohms
Motor Test Points 3 & 1 = 1400 ohms
Whirlpool Duet Door Lock/Unlock Solenoids
Unlock Solenoid = 60 ohms
Lock Solenoid = 60 ohms
Whirlpool Duet Door Lock Main Switches
To check the door lock main switches, the door must be locked. Begin by selecting a cycle and press START. You will hear the door lock solenoid engage. Unplug the washer from the wall outlet and check for continuity at the following points.
Main Switch 1 Test Points 5 & 4 = 0 ohms
Main Switch 2 Test Points 2 & 1 = 0 ohms
Whirlpool Duet Drain Pump Motor
15 ohms
Whirlpool Duet Door Switch
Door Open = 0 ohms
Door Closed = Infinity
Whirlpool Duet Heating Element
Between Terminals or test points 1 & 2 = 15 ohms
Whirlpool Duet Motor Control Unit (MCU)
Motor Connector Test Points 1 & 2 = 6 ohms
Motor Connector Test Points 1 & 3 = 6 ohms
Motor Connector Test Points 2 & 3 = 6 ohms
Motor Connector Test Points 4 & 5 = Tachometer
Whirlpool Duet Temperature Sensor
Temperature |
Proper Resistance Level |
32°F(0°C) |
35.9K Ω |
86 ° F (30° C) |
9.7K Ω |
104° F (40° C) |
6.6K Ω |
122° F (50° C) |
4.6K Ω |
140° F (60° C) |
3.2K Ω |
158° F (70° C) |
2.3K Ω |
203° F (95° C) |
1K Ω |
Whirlpool Duet Water Valve Solenoids
Hot Water Valve Solenoid = 800 ohms
Cold Water Valve Solenoid = 800 ohms