GSS MODELS

 

Self Diagnostics

To enter Self Diagnostic mode, both temperature control panel displays must be illuminated. A display

can be illuminated by pressing an adjacent temperature adjustment button. When both displays are

illuminated, set the freezer and refrigerator temperature settings to 5. Simultaneously press and hold all

4 temperature adjustment buttons for approximately 3 seconds. A flashing 0 in the refrigerator and

freezer displays will indicate that the refrigerator is in Self Diagnostic mode.

To perform a self diagnostic test, locate the test in Table 2, Diagnostic Tests.

For temperature control panels with single-digit displays, the COLDER temperature adjustment button

will increment the numbers up and the WARMER temperature adjustment button will increment the

numbers down. Use the freezer temperature adjustment buttons to enter the test code number in the

freezer display. Use the refrigerator temperature adjustment buttons to enter the test code number in

the refrigerator display. When a test code has been entered, the displays will flash to confirm the test.

Press the HOLD button for 3 seconds to begin the test.

For temperature control panels with 3-digit displays, the COLDER temperature adjustment button will

increment the numbers down and the WARMER temperature adjustment button will increment the

numbers up. Use the freezer temperature adjustment buttons to enter the test code number in the

freezer display. Use the refrigerator temperature adjustment buttons to enter the test code number in

the refrigerator display. When a test code has been entered, the displays will flash to confirm the test

code. Press any button other than a temperature adjust button to begin the test.

When testing has been completed, do one of the following things:

• Enter code 1 5 to completely reset the system.

• Enter code 1 6 to exit diagnostic mode. The temperature control panel is reset automatically.

• Unplug the refrigerator for at least 10 seconds. Test mode will terminate when the refrigerator is

plugged back in.

Test mode will terminate automatically after 15 minutes of inactivity.

Table 2. Diagnostic Tests

Freezer

Display

Refrigerator

Display

Mode Comments

0 2

Temperature control panel to main

control board communication

P on the FZ display if OK.

F on the FZ display if not OK.

0 3

Temperature control panel to

dispenser board communication

P on the FZ display if OK.

F on the FZ display if not OK.

0 4

Dispenser board to main control

board communication

P on the FZ display if OK.

F on the FZ display if not OK.

0 6

Temperature control panel selftest

See Temperature Control Panel Self-Test on page 35.

0 7

Control and sensor system selftest

See Control and Sensor Self-Test on page 36.

1 0 Open damper Damper will open, pause briefly, then close.

1 1 Fan speed test Each fan will run for 10 seconds, then stop.

1 2 100% run time

This mode runs the sealed system 100% of the time

for 1 hour.

1 3 Enter pre-chill

This places the freezer in pre-chill mode. The

refrigerator will return to normal operation on its own.

1 4 Enter defrost

This will set the refrigerator into the defrost mode. If

the cabinet is not cold when executed, this mode may

execute extremely fast. The refrigerator will return to

normal operation on its own.

1 5 Refrigerator reset Causes a system reset.

1 6 Test mode exit

Causes system to exit test mode and resets

temperature control panel.

1 7 Degree C/F

Refrigerator temperature adjust keys can be used to

change display from F to C or C to F.

 

Make a Free Website with Yola.